1. Modular pluggable technology, easy tool onsite maintenance;
2. Honeycomb briquette burning effect and the whole structure cooling technology;
3. Double-coupling IP68 protection, highest waterproof level; Metal structure, high mechanical strength;
4. Ergonomic light distribution to achieve uniform illuminating effect; Free modular serialization and full power range solution.
Applications
Street lighting
Parking lots
Roadway lighting
Path lighting
Standard Colors
White
Gray
Black
Blue+White
Photoelectric parameter specification(Lumieleds)
Product Type
Input (V)
Frequency(Hz)
Currency (mA)
Watts (W)
M1
M8
Power Facto
Driver Effec
LED Bran
CCT (K)
CRI
Lighting Effect(lm/W)
Luminous Flux(lm)
Lighting Effect(lm/W)
Luminous Flux(lm)
T18B-1
AC100-240
50/60
700
40
105±5
4200±200
110±5
4400±200
0.95
88%
Lumileds
3000 4000 5000 5700
≥70
860
50
100±5
5000±250
105±5
5250±250
1050
60
95±5
5700±300
100±5
6000±300
T18B-2
AC100-240
50/60
700
80
110±5
8800±400
115±5
9200±400
0.95
91%
860
100
105±5
10500±500
110±5
11000±500
1050
120
100±5
12000±600
105±5
12600±600
Photoelectric parameter specification(Customize)
Product Type
Input (V) Frequency(Hz)
Currency(mA)
Watts (W)
M16
Power Factor
Driver Effect
LED Brand
CCT(K)
CRI
Lighting Effect(lm/W)
Luminous(lm)
T18B-1
AC100-240
50/60
600(9 in parallel 2 in series)
30
150±8
4500±240
0.95
88%
Customized
High Power LEDs
3000 4000 5000 5700
≥70
600(14in parallel 2 in series)
30
158±8
4740±240
800(9in parallel 2 in series)
40
145±8
5800±320
800(14in parallel 2 in series)
40
153±8
6120±320
1000(9in parallel 2 in series)
50
138±8
6900±400
1000(14in parallel 2 in series)
50
147±8
7350±400
1200(9in parallel 2 in series)
60
130±8
7800±480
1200(14in parallel 2 in series)
60
140±8
8400±480
T18B-2
AC100-240
50/60
800(9in parallel 2 in series)
80
150±8
12000±640
0.95
91%
800(14in parallel 2 in series)
80
158±8
12640±640
1000(9in parallel 2 in series)
100
143±8
14300±800
1000(14in parallel 2 in series)
100
152±8
15200±800
1200(9in parallel 2 in series)
120
135±8
16200±960
1200(14in parallel 2 in series)
120
145±8
17400±960
Product working environment and packing parameter
Product Type
Working environment
Stocking Temperature
IP rate
Surge voltage
LED Life(h)
Fixture
material
Holder size(mm)
Product size (mm)
Packing (mm)
NW (kg)
GW (kg)
T18B-1
-40℃~+50℃
10%~90%RH
-40℃~+50℃
Whole lamp IP67
≥10KV
>50000
Aluminum
60±3
680*350*175
750*410*240
4.9
6.4
T18B-2
-40℃~+50℃
10%~90%RH
-40℃~+50℃
Whole lamp IP67
≥10KV
>50000
Aluminum
60±3
680*350*175
750*410*240
5.5
7.0
Internal Design Features
Dimensions
T18B-1
T18B-2
Installation Induction
Installation steps
1.Open the two clasps of the shell and open the lamp.
2. Screw the four M10 x 30 inner hexagon screw on the lamppost.
3. Insert the lamp into the lamp and tighten the four M10 x 30 inner hexagon screw on the lamp-press.
4. Connect the power cord correctly and prevent the wrong connection. The earth wire should be reliably grounded.
5. Cover the top, tighten the clasp, and complete the installation. LED Driver Maintenance
LED driver maintenance instructions
1. Open the two clasps on the shell and open the lamp.
2. Unscrew the four M4 x 10 cross head screws at both ends of the power supply.
3. Unscrew the waterproof cable between the power supply and the module.
4. Remove the damage and replace the source.
5. In turn, the components are returned to complete maintenance
LED Module Maintenance
LED module maintenance instructions
1. Open the two clasps of the shell and open the lamp.
2. Screw the four M4 x 10 cross grooves at both ends of the die set.
3. Unscrew the waterproof connector between the power supply and the module.
4. Remove the damaged module and replace the module.
5. In turn, put the components are returned to complete maintenance.